DEUTSCH  |   ENGLISH   PHONE: +49 2772 47 66 055    E-MAIL: INFO@KSISAM.COM
Accoustic Microscopes from KSISAM

Latest News

COVID-19 information – no changes for customers!


We know that it is crucial for companies around the world to align their teams as they adjust their work arrangements to slow the spread of COVID-19. Our priority during this time is the health and safety of our employees, customers, business partners and society.

We therefore monitor the changing situation on a daily basis and adjust our business processes and guidelines accordingly.

In addition, we are in daily contact with our key business partners to ensure that KSIs operations will continue with minimal disruption to enable our deliveries and services to all customers to continue.

For the many teams making the move to work anywhere, including our own, it is more important than ever to stay coordinated. You need to keep track of what is going on regardless of where you are working.

We are therefore determined to support you and your team in this time of uncertainty. We continue to offer a high quality and reliable service for our products. Our customer service, support, training, application and sales teams are ready to help you with anything.

All our resources are available for customers around the world, to ensure that you stay productive while working anywhere.

On behalf of the entire KSI team: Stay healthy, we are there for you!
 


 ©

2019-11-08: Examination on living hair


The KSI Scanning Acoustic Microscope (KSI-SAM) was used in a case study to investigate the effects of various hair preparations on the mechanical properties of hair follicles and hair roots in vivo.
In this study, several intact hair roots in the hair follicle were evaluated before and after treatment with a hair root tonic (component: leaf extract of the ginkgo tree and biotin). The reference was a living, untreated hair root. The exposure time was 60 minutes.
In the before / after comparison, a significantly positive change in the mechanical properties and strengthening of the hair root could be visualized and quantified.
 


 ©

2019-10-30: KSI Water Reactor


The KSI Water Reactor is the new All-in-One solution for the coupeling liquid, with built in CO2 Absorber & Osmosis Unit for perfect measuring conditions with your KSI Scanning Acoustic Microscope.

Key features are:
➢ Automated ultrapure osmosis water generation for usage as a coupling liquid
➢ Elimination of impurities and gas bubbles in the coupling liquid
➢ Constant and stabilized conditions in the liquid during ultrasound measurement
➢ Fully automated water level monitoring with overfill protection
➢ Independent and accurate refilling
➢ Water heating with temperature control
➢ Equipped with all safety installations necessary for production environments
➢ ESD compliant and cleanroom ready
 


 ©

2019-10-28: KSI Artificial Intelligence


The new KSI AI Scan Mode represents the future of Scanning Acoustic Microscopy using unique Artificial Intelligence SAM Imaging backed by high-precision multi-aperture, focus and depth-of-field controlled ultrasound images. Just like AI in modern cameras, our KSI AI algorithms can recognize and understand the schematic content of SAM images. KSI AI is using unique image understanding technology to extract meaningful information from acoustic images, to provide users with timely, accurate and the most relevant information with just one scan.
 


 ©

2019-09-05: Biotech and Medicine


Example: Hair examination
Scanning Acoustic Microscopy is used not only in the field of criminology, but also in the field of cosmetics and care products.
The aim of the study presented here was to investigate the effects of treatment with keratin volume foam on human hair.
It could be determined that the mechanical properties of the hair have changed.
In this particular case, the measured acoustic impedance has increased by 41% due to the treatment. In the ultrasound image, this is seen as a much brighter view of the hair.
 


Video

Scanning Acoustic Microscopy: 4D Software

 © A short demonstration of the KSI 4D software.
Scanning Acoustic Microscopy: Arbeiten mit dem KSI v8

 © This video depicts how to change a transducer, how to place a sample and the scan process itself.
Scanning Acoustic Microscopy: Reduzierung von Turbulenzen im Wasser

 © High Speed and acceleration are a necessity in the modern QC to ensure the demanded throughput and to reduce costs. This creates a problem in the field of scanning acoustic microscopy since high speed equals strong turbulences. KSI developed a solution for this issue.
Scanning Acoustic Microscopy: Working Principle

 © A short introduction in the workings of an acoustic microscope. ECHO mode, TRANSMISSION mode as well as the impact of different surfaces will be explained.
Präsentation v-series und KSI VISION-Software

 © KSI - Kraemer Sonic Industries GmbHDiscover the new scanning acoustic microscope of KSI v-series. In this video you can see a short demonstration of our system. You can also see the KSI VISION software with an introduction how to use it and software options.

Innovation for over 30 years

Acoustic Microscopy - best personal

Custom SAM Solutions


especially designed and built according to customer requests.

Acoustic Microscopy scanning technology

Standard SAM Solutions


are also provided by KSI with an excellent pricing. The v-series has an outstanding performance for the most common applications in research and production.

Acoustic Microscopy high end scanners

SAM and AMI Innovations


for Bonded Wafers, MEMS, Through-silicon Vias (TSV), LEDs, Sensor, IGBT, PCB, Automotive, Air and Defense, Bonding Layers, Defects, Delaminations, Voids, Cracks and Porosity. Bio Med and Geology Applications.

Ultrasound and Acoustic Micro Imaging

 © KSI

KSI SAM: Non-destructive testing and quantitative measuring of materials

For many years, we are supplying Acoustic Microscopes, Transducer, Pulser and Receiver worldwide. The well-known KSI quality is a guarantee for the best results.

The new patent based developed streamlined shape of the Transducer reduces turbulences, air bubbles and cavitations in coupling fluid significantly. This allows an increase of the scanning speed up to 50% with the correspondent electronics.